- Product Description
- Parameter
- Size
- Certification
-
1 General Characteristics
1.1 Application
This specification is applied to the micro switch (M12 water‑proof series ) for general applications.
1.2 Temperature Range
Operating Temperature Range: -40℃ to +125℃
Preservative Temperature Range: -40℃ to +125℃1.3 Operating Relative Humidity
Operating Relative Humidity: ≤ 85%RH
1.4 Test Conditions
Unless otherwise specified, the atmospheric conditions for making measurements and tests are as follows:
- Ambient Temperature: 5~35 ℃
- Relative Humidity: 45~85%
- Air Pressure: 86~106Kpa (860~1060mbar)
2. Appearance, Structure and Dimensions
2.1 Appearance
The switch shall have good finishing, and no rust, crack or plating defects.
2.2 Structure & Dimensions
Refer to individual product drawing.
2.3 Markings
Refer to individual product drawing.
3. Ratings
Certification Rating Life Cycles File No. ENEC 5(3)A / 3(3)A / 0.1A 125/250VAC 25T125 50,000 10(3)A 125/250VAC 25T125 10,000 UL 0.3A 200VDC 20,000 10(3)A/5(3)A/3(3)A/0.1A 125/250VAC 0.1A 30VDC 40T125 10,000 E176026 4. Electrical Characteristics
4.1 Contact Resistance
Criteria: 150mΩ max.
Test Method: Measured by a voltage drop method at 1A Max, 5VDC. Any equipment with error not more than 5% can be used. Resistance after test is the average of 5 successive measurements.(To measure after operated 5 to 10 times)
4.2 Insulation Resistance
Criteria: 100 MΩ min.
Test Method: 500VDC voltage is applied between each pair of terminals and between the terminal and the metal frame for 60±5S.
4.3 Dielectric Voltage
Criteria: No dielectric breakdown shall occur.
Test Method:
Between non‑connected terminals: 1000V 50‑60Hz 10mA 60S
Between terminals and the plastic or metal body: 1500V 50‑60Hz 10mA 60S5. Mechanical Characteristics
Item Criteria Test Method 5.1 Operating Force See product drawing Apply a tension load on the midpoint of the actuator (or 1mm to the tip of the shaft) to supply a pressure vertically from its free position to operating position. 5.2 Releasing Force See product drawing A static load shall be reduced to the tip of actuator in operating direction to change component from operating position to release position. 5.3 Free Position See product drawing The position where the actuator lead the Displacements when its out of force or the force is not enough to drive the actuator. 5.4 Operating Position See product drawing The distance from the end of operating component to the center of mount hole when switch is being transformed. 5.5 Pre Travels See product drawing The distance vertically through, which the midpoint of the actuator (or tip of the shaft) trip move from its free position to operating position. 5.6 Differential Travel See product drawing The distance from operating position to release position. 5.7 Over Travel See product drawing The displacements of actuator form operation to total travel position. 5.8 Terminal Strength Shall be free from terminal looseness, damage and insulator breakage. The electrical performance requirements specified in section 4.3 shall be satisfied. A static load of 50N shall be applied to the tip of terminal in a desired direction for 10 ± 1s. The test shall be done once per terminal. 6. Durability characteristics
6.1 Mechanical Life
Criteria: After test, Contact resistance: 500mΩ max. Insulation resistance:50MΩ min. The electrical performance requirements specified in item 4.3 shall be satisfied. The switch shall be free from abnormalities in appearance & construction. Operating force: within ±30% initialization value.
Test Method: 1,000,000 cycles of operation shall be performed continuously at a rate of 60 cycles per minute without load.
6.2 Operating Life with Load
Criteria: After test, Insulation resistance:10MΩ min. The electrical performance requirements specified in item 4.3 shall be satisfied. The switch shall be free from abnormalities in appearance & construction. Operating force: within ±30% initialization value.
Test Method:
UL(UL61058):10,000 cycles of operation shall be performed continuously at a rate of 15 cycles per minute with load as follow: Refer to individual product drawing (Resistive Load)
CQC(GB15092.1)/ENEC(EN61058‑1):10,000 cycles of operation shall be performed continuously at a rate of 15 cycles per minute with load as follow: Refer to individual product drawing (Resistive Load)7. Weather Proof Characteristics
7.1 Cold Proof
Criteria: After test, Contact resistance: 500mΩ Max. Insulation resistance:50MΩ Min.
Test Method: After testing at –40 ± 2°C for 96 hours, the switch shall be allowed to stand under normal temperature and humidity conditions for 1 hour, and measurement shall be made within 1 hour after that. Water drops shall be eliminated.
7.2 Hot Proof
Criteria: After test, Contact resistance: 500mΩ Max. Insulation resistance:50MΩ Min.
Test Method: After testing at 125± 2°C for 96 hours, the switch shall be allowed to stand under normal temperature and humidity conditions for 1 hour, and measurement shall be made within 1 hour after that. Water drops shall be eliminated.
7.3 Moisture Resistance
Criteria: After test, Contact resistance: 500mΩ Max. Insulation resistance:50MΩ Min. The electrical performance requirements specified in item 4.3 shall be satisfied. The switch shall be free from abnormalities in appearance & construction.
Test Method: After testing at 40± 2°C ,90~95% RH for 96 hours, the switch shall be allowed to stand under normal temperature and humidity conditions for 1 hour, and measurement shall be made within 1 hour after that. Water drops shall be eliminated.
8. Material List
Material List No. Parts Name Quantity Material and Specifications Prevent fire grade Remarks 1 Cover 1 PBT UL94V‑0 2 Case 1 PBT UL94V‑0 4 Sealing gasket 1 Silicon 5 COM Terminal 1 Cu Alloy Ag PLATED 6 NO Terminal 1 Cu Alloy Au PLATED 7 NO Contact 1 Ag Alloy Au PLATED 8 NC Terminal 1 Cu Alloy 9 Moving Plate 1 Cu Alloy Au PLATED 10 MP Contact 1 Ag Alloy Au PLATED 11 Spring 1 STAINLESS STEEL 12 Wire & Connector 1 24AWG blue wire UL1569; CWB or JST green connector 2 pcs Blue wire 9. Operating data diagram
OF: Operating Force
OP: Operating Position
TT: Total Travel
RF: Release Force
TTP: Total Travel Position
TF: Total travel Force
RP: Release Position
FP: Free Position
PT: Pre Travel
OT: Over Travel
DT: Differential Travel
-
1.Mechanical Characteristics
Mechanical Characteristics ITEM Standards OF Operating Force 150gf Max. RF Release Force 30gf Min. OP Opearting Position 9.3±1.0mm DT Differential Travel 0.6mm Max. FP Free Position 12.0mm Max. TTP Total Travel Position 8.1mm Max. 2.Electrical Characteristics
Electrical Characteristics Load 5(3)A 125/250VAC 50,000cycles Insulation Resistance 100Mohms Min. Dielectric Strength(50-60HZ) 1000VAC Between terminals 1500VAC Between terminals and ground 3.Other Characteristics
Other Characteristics ITEM Standards Mechanical Life 1,000,000 cycles Opearting Temperature 40T125 Protection class IP67(except terminal) -

-




Product Inquiry
Do you have any questions about purchasing products or solutions that interest you? Fill out the form and we will reply within 7 working days.
Latest Products